Constant-Temperature Distributed Temperature Sensing (DTS) System for Oil & Geothermal Applications
Constant-Temperature Distributed Temperature Sensing (DTS) System for Oil & Geothermal Applications
Model: DTS-BLY-5S (CT-10km)

Measures continuous temperature profiles and abnormal-temperature locations along the fiber. Select range, fiber type, channels and sensing cable for the specified model.
Typical applications
Downhole geothermal wells, downhole oil wells, CCUS projects, gas storage facilities, compressed air energy storage systems, and other applications with higher requirements for absolute temperature accuracy.
Spatial resolution, sampling interval and location accuracy are distinct quantities. Temperature accuracy depends on fiber length, acquisition time, temperature range and cable configuration; optimum values are not necessarily simultaneous.
Spatial resolution uses the 10%–90% step-response criterion and the ± spatial-extent notation used in this datasheet. Location accuracy is specified separately. Compare specifications using the same definitions and test conditions.
Technical specifications
| Parameter | Specification |
| Fiber Type | Multimode Fiber |
| Center Wavelength | 1550 nm |
| Measurement Range | 10 km |
| Spatial resolution | ±0.5 m |
| Location Accuracy | ±0.5 m |
| Measurement Time | ≤2 s/km(software-adjustable) / software-adjustable |
| Temperature Measurement Range | -200°C to 450°C (depending on cable type) Depending on cable type |
| Temperature Accuracy | ±0.05°C@2km, ±0.2°C @ 10 km; |
| Ambient temperature drift coefficient | Temperature indication drift ≤0.02 °C per 1 °C ambient change (temperature-stabilized components) |
| Temperature Resolution | 0.01°C |
| Measurement Channels | Default 1 channel; up to 16 channels |
| Optical Connector | FC/APC |
| Power Supply | DC 24 V; maximum power consumption ≤96 W |
| Operating Temperature | -10°C to 40°C |
| Storage Temperature | -20°C to 70°C |
| Communication Interfaces | 2 × RS-232, 1 × RJ45 Ethernet |
| Dimensions (W × D × H) | 482.6 × 327.7 × 132.8 mm (3U rack-mount) |
| Weight | 12 kg |
For advice on distributed temperature sensing DTS, share your monitoring distance, installation environment and integration requirements with our engineering team. We can help assess sensor placement, commissioning and acceptance criteria for your project.