DISTRIBUTED FIBER SENSING · FROM SIGNAL TO INSIGHTwxbuliyuan@163.com ↗
LIGHTRAMANFIBER OPTIC SENSING
◎ English
Language中文 ↗English ✓Español ↗العربية ↗Português ↗Français ↗Deutsch ↗
BOTDR1000

Brillouin optical time-domain reflectometer

Single-ended BOTDR for linear assets accessible from one fiber end.

BOTDR1000 Brillouin Optical Time-Domain Reflectometer

BOTDR1000 Brillouin Optical Time-Domain Reflectometer

BOTDR1000

Principle and applications

Uses spontaneous Brillouin backscattering and time-domain localization. Single-core, single-ended access measures Brillouin frequency shift and temperature or strain along the fiber. Maximum configured range is 60 km; typical acquisition time is 60–300 s/channel.

Brillouin frequency shift responds to both temperature and axial strain. Strain measurement requires temperature compensation; temperature measurement requires strain isolation or correction. One frequency-shift trace cannot independently determine both unknown quantities.

Optical sensing and transmission resist EMI and support continuous profiles, event location, fiber-fault monitoring and long-term condition management. Select the cable and complete system for the applicable hazardous-area conditions.

Range, spatial resolution, averaging time and accuracy are configuration-dependent and not necessarily achieved simultaneously. Temperature range depends on the fiber and jacket; strain requires reliable mechanical transfer into the fiber.

Technical specifications

ItemSpecification
System location error<1 m under the specified configuration and calibration conditions
Fiber TypeStandard single-mode fiber
Fiber ConfigurationSingle fiber core, single-ended measurement
Measurement Range5km/20km/50km/60km
Measurement Channels1/2/4/8
Configurable as required
Measurement Time60-300 s/channel (typical)
Measurement Range(-40~+100)°C/(-10000~+10000)με
(-40 to +100) °C / (-10000 to +10000) με
Measurement Accuracy±1°C/±20με
±1 °C / ±20 με
Measurement Resolution0.2°C/4με
0.2 °C / 4 με
Sampling Interval0.1/0.2/0.4/0.8m
Match spacing to the configured range; 0.1 m applies to the 5 km configuration
Spatial resolution1–50 m (depending on cable loss and measurement settings)
Alarm ModeFixed threshold, differential, and zonal differential
Alarm Zones500 zones/channel
Alarm thresholds can be set independently for each zone
Optical ConnectorFC/APC
Storage Capacity1TB
Operating Conditions−10 to +50 °C; 0–95% RH (non-condensing)
Power Supply220 VAC, -48 VDC (optional)
Dimensions (W x D x H)483 × 447 × 133 mm (19-inch rack-mount)
Weight<15kg

Product and application views

BOTDR1000BOTDR1000

For advice on BOTDR interrogator, share your monitoring distance, installation environment and integration requirements with our engineering team. We can help assess sensor placement, commissioning and acceptance criteria for your project.

LET'S BUILD YOUR SOLUTION

Your site. Our next conversation.

Tell us about your assets and requirements. Let’s find the right sensing approach.

CONTACT OUR TEAM

Solution consultation

Tell us what you need. Our sales team will get in touch.

Emailwxbuliyuan@163.comPhone+8618651589558WhatsAppStart a conversation ↗